6,375 research outputs found
An obstruction based approach to the Kochen-Specker theorem
In [1] it was shown that the Kochen Specker theorem can be written in terms
of the non-existence of global elements of a certain varying set over the
partially ordered set of boolean subalgebras of projection operators on some
Hilbert space. In this paper, we show how obstructions to the construction of
such global elements arise, and how this provides a new way of looking at
proofs of the theorem.Comment: 14 pages, 6 figure
Stress redistribution due to creep in nimonic 90 ministry of aviation contract no. PD/28/021 report for the period January 1964 - June 1965: part 1
The period covered by this report has been devoted to the design,
construction development and calibration of a special apparatus to simulate
the stress redistribution conditions occurring during the creep of a cooled
turbine blade. The experimental assembly consists of two creep machines,
each operating at a different temperature, so controlled that a load is
shared between them. maintaining equal creep strains (and in consequence
equal creep rates) in each specimen. The stress in each specimen and the
creep strain of the pair are automatically measured and recorded by a
specially developed unit. Some preliminary results on an aluminium alloy
are presented
Aircraft electromagnetic compatibility
Illustrated are aircraft architecture, electromagnetic interference environments, electromagnetic compatibility protection techniques, program specifications, tasks, and verification and validation procedures. The environment of 400 Hz power, electrical transients, and radio frequency fields are portrayed and related to thresholds of avionics electronics. Five layers of protection for avionics are defined. Recognition is given to some present day electromagnetic compatibility weaknesses and issues which serve to reemphasize the importance of EMC verification of equipment and parts, and their ultimate EMC validation on the aircraft. Proven standards of grounding, bonding, shielding, wiring, and packaging are laid out to help provide a foundation for a comprehensive approach to successful future aircraft design and an understanding of cost effective EMC in an aircraft setting
The 1974 outlook for food and agriculture
Food industry and trade ; Agriculture
Prospects for food and agriculture in 1975
Agriculture ; Food industry and trade
Simulating Quantum Mechanics by Non-Contextual Hidden Variables
No physical measurement can be performed with infinite precision. This leaves
a loophole in the standard no-go arguments against non-contextual hidden
variables. All such arguments rely on choosing special sets of
quantum-mechanical observables with measurement outcomes that cannot be
simulated non-contextually. As a consequence, these arguments do not exclude
the hypothesis that the class of physical measurements in fact corresponds to a
dense subset of all theoretically possible measurements with outcomes and
quantum probabilities that \emph{can} be recovered from a non-contextual hidden
variable model. We show here by explicit construction that there are indeed
such non-contextual hidden variable models, both for projection valued and
positive operator valued measurements.Comment: 15 pages. Journal version. Only minor typo corrections from last
versio
Spherically Symmetric Solutions to Fourth-Order Theories of Gravity
Gravitational theories generated from Lagrangians of the form f(R) are
considered. The spherically symmetric solutions to these equations are
discussed, paying particular attention to features that differ from the
standard Schwarzschild solution. The asymptotic form of solutions is described,
as is the lack of validity of Birkhoff's theorem. Exact solutions are presented
which illustrate these points and their stability and geodesics are
investigated.Comment: 10 pages, published versio
S-Nitrosoglutathione reduces asymptomatic embolization after carotid angioplasty
Background: The major complication of carotid angioplasty is embolic stroke, which may occur after balloon inflation and deflation or in the early postintervention period. Platelet adhesion and aggregation to the angioplasty site with subsequent embolization seems to plays a major role in early postangioplasty embolization and stroke. During this period, asymptomatic embolic signals can be detected in patients by transcranial Doppler ultrasound despite aspirin and heparin treatment. S-Nitrosoglutathione (GSNO) is a nitric oxide donor that appears to have relative platelet specificity. We evaluated its effectiveness in reducing embolization after carotid angioplasty.
Methods and results: Sixteen patients undergoing carotid angioplasty and stenting for symptomatic 70% internal carotid artery stenosis were randomized in a double-blind manner to GSNO or placebo given after surgery for 90 minutes. All patients were pretreated with aspirin and given heparin for 24 hours after the procedure. Transcranial Doppler recordings were made from the ipsilateral middle cerebral artery for 1 hour before treatment and at 0 to 3, 6, and 24 hours after treatment. GSNO resulted in a rapid reduction in the frequency of embolic signals of 95% at 0 to 3 hours and 100% at 6 hours (P=0.007 and P=0.01 versus placebo, respectively). In the placebo group, 2 patients experienced ipsilateral stroke after the angioplasty. No cerebrovascular events occurred in the GSNO group.
Conclusions: S-Nitrosoglutathione was highly effective in rapidly reducing the frequency of embolic signals after endovascular treatment for symptomatic high-grade carotid stenosis
Volume Weighted Measures of Eternal Inflation in the Bousso-Polchinski Landscape
We consider the cosmological dynamics associated with volume weighted
measures of eternal inflation, in the Bousso-Polchinski model of the string
theory landscape. We find that this measure predicts that observers are most
likely to find themselves in low energy vacua with one flux considerably larger
than the rest. Furthermore, it allows for a satisfactory anthropic explanation
of the cosmological constant problem by producing a smooth, and approximately
constant, distribution of potentially observable values of Lambda. The low
energy vacua selected by this measure are often short lived. If we require
anthropically acceptable vacua to have a minimum life-time of 10 billion years,
then for reasonable parameters a typical observer should expect their vacuum to
have a life-time of approximately 12 billion years. This prediction is model
dependent, but may point toward a solution to the coincidence problem of
cosmology.Comment: 35 pages, 8 figure
- …